Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Aura - Panel
tab1
styles{"body":{"text":{"color":"#465671","textAlign":"left","fontWeight":"normal","fontSize":14}},"header":{"backgroundColor":{"color":"#002d72"}},"headline":{"alignment":{"horizontal":"start"},"text":{"text":"Terminology & Definitions","color":"#ffffff","textAlign":"left","fontWeight":"bold","fontSize":26},"border":{"color":"#002d72","style":"solid","top":false,"right":false,"bottom":true,"left":false,"width":2}},"base":{"backgroundColor":{"color":"#f3f4f9"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body<p><br /></p>

Glossary of the Empire Building Challenge Knowledge Base.



Aura - Panel
tab1
styles{"body":{"text":{"color":"#465671","textAlign":"left","fontWeight":"normal","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#0149b0","width":4,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body<p><br /></p>


Expand
titleCarbon Neutral Buildings

Buildings that produce no net greenhouse gas emissions directly or indirectly. Carbon neutrality spans multiple scopes of associated greenhouse gas emissions including (1) operations on-site and via emissions associated with third-parties delivering energy or products to site and (2) embodied carbon emissions from the full lifecycle and production of construction materials. Emissions are often referred to as scope 1, 2 and 3: Essentially, scope 1 and 2 are those emissions that are owned or controlled by a company, whereas scope 3 emissions are a consequence of the activities of the company but occur from sources not owned or controlled by it.


Expand
titleCoefficient of Performance (COP)

The ratio of the amount of heat delivered from a heat pump over the amount of electrical input. For example, a heat pump has a COP of 5.0 if it can deliver 5 units of heat for one unit of electricity input. A COP of 1.0 is resistance heat like a toaster or hair dryer.  


Expand
titleFacade Overclad

An additional weather barrier installed overtop an existing facade to increase building envelope energy performance, thermal comfort and to reduce ongoing building maintenance.  


Expand
titleHeat Recovery/Recycling

The capture and reuse of waste heat coming from different sources such as building ventilation system, condenser water loop, wastewater or steam condensate return. Heat recovery system can often incorporate often incorporating thermal storage techniques, see Time Independent Energy Recovery (TIER). 


Expand
titleNet Present Value (NPV)

An analysis of project cash flow over a set period of time which incorporates inflation and the time value of money; the "upfront" lifetime value of a project. A positive NPV yields a Return on Investment (ROI).


Expand
titleOn-site Fossil Fuel

Fossil fuel consumed typically via combustion within a building for the purpose of heating, cooling, domestic hot water production, or power generation.


Expand
titleReturn on Investment (ROI)

The ratio between net income or savings from a project investment over a set period of time. ROI is typically presented as a percentage for the period of one (1) year.


Expand
titleSimple Payback

Economic benefits yielded from investment in a project. Simple payback is typically presented in the time (e.g. years) it takes to recover an investment, but does not take into account variations in cash flow over time nor considers the time value of money.


Expand
titleStrategic Decarbonization Assessment (SDA)

A mid- long-term financial planning method for building owners to manage carbon emissions and energy use. 


Expand
titleThermal Distribution

The means by which heat or cool is moved throughout a building. This includes moving heat through various heat transfer media including but not limited to water, steam, refrigerant gas, or ducted air. 


Expand
titleThermal Energy Network (TEN)

Infrastructure that enables sharing of heat through a variety of thermal transfer media between heat customers and producers who extract heat from various sources using a variety of technologies.


Expand
titleThermal Storage

The storage of heat or cool in various media and using a variety of technologies for use at a later time.


Expand
titleWaste Heat

Heat or cooling which is typically rejected to the air and not recovered. Waste Heat sources include sanitary sewer heat, heat rejected from air source heat pumps, cooling tower heat, heat lost from ventilation exhaust, steam condensate return, underground transportation etc.





HTML
<script type="text/javascript" >
   jQuery(document).ajaxComplete(function() {
      if(jQuery('.ia-fixed-sidebar.collapsed').length == 0 ) {
         jQuery('.expand-collapse-trigger').click();
     };
   });
</script>

<style type="text/css">
#title-text { display: none;}
.aura-headline {
padding-bottom: 0px !important;
}
.aura-header {
padding-left: 10px !important;
padding-right: 10px !important;
padding-top: 10px !important;
padding-bottom: 10px!important;
}
.aura-body {
padding-top: 10px !important;
padding-left: 10px !important;
padding-right: 10px !important;
padding-bottom: 10px !important;
}
</style>