styles{"body":{"text":{"color":"#465671","textAlign":"left","fontWeight":"normal","fontSize":14}},"header":{"backgroundColor":{"color":"#002d72"}},"headline":{"alignment":{"horizontal":"start"},"text":{"text":"Resource Efficient Electrification (REE) and SRs","color":"#ffffff","textAlign":"left","fontWeight":"bold","fontSize":26},"border":{"color":"#002d72","style":"solid","top":false,"right":false,"bottom":true,"left":false,"width":2}},"base":{"backgroundColor":{"color":"#f3f4f9"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body<p><br /></p>

The Resource Efficient Electrification (REE) method of building decarbonization incorporates strategic capital planning, an integrated design process, and an incremental, network-oriented approach to deliver building heating, cooling, and ventilation which:

  • requires limited or no combustion,
  • enables carbon neutrality,
  • is highly efficient at low design temperatures and during extreme weather,
  • is highly resilient, demand conscious, and energy grid-interactive,
  • reduces thermal waste by capturing as many on-site or nearby thermal flows as possible, and
  • incorporates realistic and flexible implementation strategies by optimizing and scheduling low carbon retrofits phase-in.



Aura - Panel
tab1
styles{"body":{"text":{"color":"#002d72","textAlign":"left","fontWeight":"normal","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"},"text":{"text":"Decarbonization Roadmap","color":"#002d72","textAlign":"left","fontWeight":"normal","fontSize":26}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#002d72","width":4,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body<p><br /></p>


Expand
titlelearn more


Section


Column
width40%

The figure below illustrates a conceptual framework for accomplishing these objectives and overcoming the mental traps described in a previous page. Specific measures and sequencing will be highly bespoke for a given building, but engineers and their owner clients can use this bucketed “RRRR/R” framework to place actionable projects in context of an overarching decarbonization roadmap:


Column
width60%





Aura - Panel
tab1
styles{"body":{"text":{"color":"#002d72","textAlign":"left","fontWeight":"normal","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"},"text":{"text":"The Five Rs","color":"#002d72","textAlign":"left","fontWeight":"normal","fontSize":26}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#002d72","width":4,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body<p><br /></p>


Expand
titlelearn more

Reduce

Expand
titlelearn more
  • Loads, with envelope improvements and advanced controls.
  • The use of steam-fed radiators and forced air by moving to hydronic and/or distributed systems.
  • Supply temperatures to ranges of optimal heat pump performance.

Recover

Expand
titlelearn more


Section


Column
width40%
  • Store heat where necessary.
  • Eliminate "economizer" waste. Rejecting heat is wasting energy.
  • Identify simultaneous or correlated heating & cooling opportunities within daily load profiles to create a thermal network
  • include other creative and opportunistic heat sources such as steam condensate return, ventilation exhaust, or data centers


Column
width60%



Replace

Expand
titlelearn more
  • Fossil combustion equipment with the appropriate heat pump technology(ies), to the degree techno-economically feasible, with emphasis on efficiently meeting the bulk of the building’s annual load.

    Expand
    titlescreenshot


  • Not just 1:1 swap! REDUCE & RECOVER first, then size heat pumps to top-off the remaining heat/cool imbalance on a thermal network. 

    Expand
    titlescreenshot


  • Peak condition challenges don’t have to prevent partial electrification and electrification enabling decisions today
  • Give separate consideration to challenging loads, extreme conditions
  • Retaining resilience & optionality in the transition

Renew

Expand
titlelearn more
  • Auxiliary heat supply to meet the most challenging load conditions as the need is fully understood and technically, economically and environmentally resilient.

Remove

Expand
titlelearn more
  • Redundant fossil heat capacity proven to be no longer necessary.





HTML
<script type="text/javascript" >
   jQuery(document).ajaxComplete(function() {
      if(jQuery('.ia-fixed-sidebar.collapsed').length == 0 ) {
         jQuery('.expand-collapse-trigger').click();
     };
   });
</script>

<style type="text/css">
#title-text { display: none;}
.aura-headline {
padding-bottom: 0px !important;
}
.aura-header {
padding-left: 10px !important;
padding-right: 10px !important;
padding-top: 10px !important;
padding-bottom: 10px!important;
}
.aura-body {
padding-top: 10px !important;
padding-left: 10px !important;
padding-right: 10px !important;
padding-bottom: 10px !important;
}
</style>