styles{"body":{"text":{"color":"#465671","textAlign":"left","fontWeight":"normal","fontSize":14}},"header":{"backgroundColor":{"color":"#002d72"}},"headline":{"alignment":{"horizontal":"start"},"text":{"text":"Resource Efficient Electrification (REE) and SRs","color":"#ffffff","textAlign":"left","fontWeight":"bold","fontSize":26},"border":{"color":"#002d72","style":"solid","top":false,"right":false,"bottom":true,"left":false,"width":2}},"base":{"backgroundColor":{"color":"#f3f4f9"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body<p><br /></p>

The Resource Efficient Electrification (REE) method of building decarbonization incorporates strategic capital planning, an integrated design process, and an incremental, network-oriented approach to deliver building heating, cooling, and ventilation which:

  • requires limited or no combustion,
  • enables carbon neutrality,
  • is highly efficient at low design temperatures and during extreme weather,
  • is highly resilient, demand conscious, and energy grid-interactive,
  • reduces thermal waste by capturing as many on-site or nearby thermal flows as possible, and
  • incorporates realistic and flexible implementation strategies by optimizing and scheduling low carbon retrofits phase-in.



Aura - Panel
tab1
styles{"body":{"text":{"color":"#002d72","textAlign":"left","fontWeight":"normal","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"},"text":{"text":"Decarbonization Roadmap","color":"#002d72","textAlign":"left","fontWeight":"normal","fontSize":26}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#002d72","width":4,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body<p><br /></p>


Expand
titlelearn more...


Section


Column
width40%

The figure below illustrates a conceptual framework for accomplishing these objectives and overcoming the mental traps described in a previous page. Specific measures and sequencing will be highly bespoke for a given building, but engineers and their owner clients can use this bucketed “RRRR/R” framework to place actionable projects in context of an overarching decarbonization roadmap:


Column
width60%





Aura - Panel
tab1
styles{"body":{"text":{"color":"#002d72","textAlign":"left","fontWeight":"normal","fontSize":14}},"header":{"backgroundColor":{"color":"#ffffff"}},"headline":{"alignment":{"horizontal":"start"},"text":{"text":"The Five Rs","color":"#002d72","textAlign":"left","fontWeight":"normal","fontSize":26}},"base":{"border":{"bottom":false,"left":true,"right":false,"top":false,"color":"#002d72","width":4,"style":"solid"},"backgroundColor":{"color":"#ffffff"},"borderRadius":{"radius":4},"boxShadow":{"shadows":[{"color":"rgba(0, 0, 0, 0.08)","x":0,"y":1,"blur":1,"spread":0},{"color":"rgba(0, 0, 0, 0.16)","x":0,"y":1,"blur":3,"spread":1}]}}}
body<p><br /></p>


Expand
titlelearn more...

Reduce

Expand
titlelearn more
  • Loads, with envelope improvements and advanced controls.
  • The use of steam-fed radiators and forced air by moving to hydronic and/or distributed systems.
  • Supply temperatures to ranges of optimal heat pump performance.

Recover

Expand
titlelearn more


Section


Column
width40%
  • Store heat where necessary.
  • Eliminate "economizer" waste. Rejecting heat is wasting energy.
  • Identify simultaneous or correlated heating & cooling opportunities within daily load profiles to create a thermal network
  • include other creative and opportunistic heat sources such as steam condensate return, ventilation exhaust, or data centers


Column
width60%



Replace

Expand
titlelearn more
  • Fossil combustion equipment with the appropriate heat pump technology(ies), to the degree techno-economically feasible, with emphasis on efficiently meeting the bulk of the building’s annual load.

    Expand
    titlescreenshot


  • Not just 1:1 swap! REDUCE & RECOVER first, then size heat pumps to top-off the remaining heat/cool imbalance on a thermal network. 

    Expand
    titlescreenshot


  • Peak condition challenges don’t have to prevent partial electrification and electrification enabling decisions today
  • Give separate consideration to challenging loads, extreme conditions
  • Retaining resilience & optionality in the transition

Renew

Expand
titlelearn more

Auxiliary heat supply to meet the most challenging load conditions as the need is fully understood and technically, economically and environmentally resilient.

Remove

Expand
titlelearn more

Redundant fossil heat capacity proven to be no longer necessary.





HTML
<script type="text/javascript" >
   jQuery(document).ajaxComplete(function() {
      if(jQuery('.ia-fixed-sidebar.collapsed').length == 0 ) {
         jQuery('.expand-collapse-trigger').click();
     };
   });
</script>

<style type="text/css">
#title-text { display: none;}
.aura-headline {
padding-bottom: 0px !important;
}
.aura-header {
padding-left: 10px !important;
padding-right: 10px !important;
padding-top: 10px !important;
padding-bottom: 10px!important;
}
.aura-body {
padding-top: 10px !important;
padding-left: 10px !important;
padding-right: 10px !important;
padding-bottom: 10px !important;
}
</style>